Источник питания для светодиодного освещения серии LPV. Входное напряжение: от 90 до 264 В. Выходная мощность 60 Вт, Выход DC 12 В. Режим стабилизации ток/напряжение: напряжение. Степень защиты: IP67. Напряжение изоляции вход-выход: 3 кВ Рабочая температура: от минус 30 до плюс 70 °C
Технические характеристики
MODEL | LPV-60-12 |
---|---|
DC VOLTAGE | 12V |
RATED CURRENT | 5A |
CURRENT RANGE | 0 ~ 5A |
RATED POWER | 60W |
RIPPLE & NOISE (max.) Note.2 | 120mVp-p |
VOLTAGE TOLERANCE Note.3 | ±5.0% |
LINE REGULATION | ±1.0% |
LOAD REGULATION | ±2.0% |
SETUP, RISE TIME Note.6 | 500ms, 20ms / 230VAC 500ms, 20ms / 115VAC at full load(for 5~36V) ; 500ms, 30ms / 230VAC 500ms, 30ms / 115VAC at full load(for 48V) |
HOLD UP TIME (Typ.) | 50ms/230VAC 16ms/115VAC at full load |
VOLTAGE RANGE Note.4 | 90 ~ 264VAC 127 ~ 370VDC |
FREQUENCY RANGE | 47 ~ 63Hz |
EFFICIENCY (Typ.) | 83% |
AC CURRENT (Typ.) | 1.2A/115VAC 1A/230VAC |
INRUSH CURRENT(Typ.) | COLD START 60A(twidth=525μs measured at 50% Ipeak) at 230VAC |
MAX. No. of PSUs on 16A CIRCUIT BREAKER | 3 units (circuit breaker of type B) / 6 units (circuit breaker of type C) at 230VAC |
LEAKAGE CURRENT | 0.25mA / 240VAC |
OVER LOAD | 110 ~ 150% rated output power |
Protection type : Hiccup mode, recovers automatically after fault condition is removed | |
OVER VOLTAGE | 13.8 ~ 16.2V |
Protection type : Shut down o/p voltage, re-power on to recover | |
WORKING TEMP. | -30 ~ +70℃ (Refer to "Derating Curve") |
WORKING HUMIDITY | 20 ~ 90% RH non-condensing |
STORAGE TEMP., HUMIDITY | -40 ~ +80℃, 10 ~ 95% RH |
TEMP. COEFFICIENT | ±0.03%/℃ (0 ~ 50℃) |
VIBRATION | 10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes |
SAFETY STANDARDS | UL879(except for LPV-60-5), UL1310(except for LPV-60-5), CSA C22.2 No. 207-M89(except for LPV-60-5, LPV-60-48), CAN/CSA C22.2 No. 223-M91(except for LPV-60-5,LPV-60-48), BIS IS15885(for LPV-60-12,LPV-60-24 only), EAC TP TC 004, IP67, IEC60950-1:2005+A2:2013 approved ; design refer to TUV EN60950-1 |
WITHSTAND VOLTAGE | I/P-O/P:3KVAC |
ISOLATION RESISTANCE | I/P-O/P:>100M Ohms / 500VDC / 25℃/ 70% RH |
EMC EMISSION | Compliance to EN55032 (CISPR32) Class B, EN61000-3-2 Class A, EN61000-3-3, EAC TP TC 020 |
EMC IMMUNITY | Compliance to EN61000-4-2,3,4,5,6,8,11, EN55024, light industry level, criteria A, EAC TP TC 020 |
MTBF | 732Khrs min. MIL-HDBK-217F (25℃) |
DIMENSION | 162.5*42.5*32mm (L*W*H) |
PACKING | 0.4Kg; 32pcs/13.8Kg/0.63CUFT |
- All parameters NOT specially mentioned are measuted at 230VAC input, rated load and 25°C of ambient temperature.
- Ripple & noise are measuted at 20MHz of bandwidth by using a 12" twisted pair—wire terminated with a 0.1uf & 47uf parallel capacitor.
- Tolerance: includes set up tolerance, line regulation and load regulation.
- Derating may be needed under low input voltage. Please check the static characteristics for more details.
- The power supply is considered as a component that will be operated in combination with final equipment. Since EMC performanse will be affected by the complete installation, the final equipment manufacturers must re-quality EMC Directive on the complete installation again.
- Length of set up time is measured at first cold start. Turning ON/OFF the power supply may lead to increase of the set up time.
- Suitable for indoor use or outdoor use without direct sunlight exposure. Please avoid immerse in the water over 30 minute.
- The ambient temperatute derating of 3.5°C/1000m with fanless models and of 5°C/1000m with fan models for operating altitude higher than 2000m(6500ft).
- For any application note and IP water proof function installation caution, please refer our user manual befote using. https://www.meanwell.com/Upload/PDF/LED_EN.pdf
- This product is not intended for LED applications in the EU.(ln the EU NPF/LPF/XLG series are recommended.)
- To fulfill requirements of latest ErP regulation for lighting luminaires, this LED Driver can only be used behind a switch without permanently connected to mains.
Вес: 0.4 kg