Общие данные

Тип EasyTREK SP-500
Transducer / enclosure materials PP, PVDF
Process temperature PP, PVDF transducers -30 °C … +90 °C [-20 °F … 190 °F]
Ambient temperature -30 °C … +80 °C [-20 °F … 175 °F]
Pressure(1) (Absolute) 0.05 – 0.3 MPa (0.5 – 3 bar) [7.25 psi – 43.5 psi]
Seals PP transducer: EPDM; All other transducer versions: FPM
Ingress protection IP68
Power supply 10(3) – 36 V DC with HART communication
40 mW – 720 mW, Galvanic isolation; protection against surge transients
Accuracy(2) ± (0.1% measured + 0.025% max.) or ± (0.05% max.) whichever is greater
Resolution Depending on the measured distance: <2 m: 1 mm, 2 – 5 m: 2 mm, 5 – 10 m: 5 mm, >10 m: 10 mm
[<6.5 ft: 40 mil, 6.5 ft – 16 ft: 78 mil, 16 ft – 32 ft: 200 mil, >32 ft: 400 mil]
Outputs  
Analogue 4 – 20 mA, (3.9 – 20.5 mA), Rtmax = (Ut – 10 V) / 0.02 A, Galvanic isolation; protection against surge transients
  SPDT relay, 30 V / 1 A DC; 48 V / 0.5 A AC
Serial communication HART interface (terminal resistor ≥ 250 Ohm)
Programming / diagnostic interface 3.3 V LVDS, 100 mA max., Galvanic isolated
Electrical connection 6 x 0.5 mm2 [20 AWG] shielded cable Ø6 mm x 5 m (available max. length 30 m)
Electrical protection Class III SELV

(1) For pressures below 1 bar consult with your representative at NIVELCO

(2) Under optimal circumstances of reflection and stabilised transducer temperature.

(3) Only partial operation is provided. Reliable operation without any restrictions is guaranteed at >11 V terminal voltage.

SPECIAL DATA FOR PP, PVDF AND PTFE TRANSDUCERS

Type SP-5A- SP-59- SP-58- SP-57- SP-56- SP-54-
Transducer material PP, PVDF
Max. measuring distance* (XM)
(m) [ft]
3 (10) 5 (17) 8 (26) 10 (33) 12 (40) 18 (60)
Min. measuring distance*
(Dead band) (Xm) [m (in)]
           
Total beam angle (-3 dB)            
Measuring frequency            
Upper process connection            
Lower process connection            

ACCESSORIES

  • Warranty Card
  • Installation and Programming Manual
  • Declaration of Conformity