Измеритель мощности ABB D1M 20 Modbus: Power meter with aux supply 85-265 V AC/DC, Modbus RTU RS485, 2 digital inputs and 2 digital outputs, class 0.5 accuracy for active energy according to IEC 61557-12 PMD, LCD display

abb-d1m-20
D1M 20 Energy analyser for LV and MV networks, 3 or 4 wires, for balanced and unbalanced load: Voltage, current, average current, frequency, power factor, active/reactive/apparent power and energy, average active/reactive/apparent power and energy, produced/consumed energy measurement, %THDV and %TH ...Читать далее

Цены

128 189 KZT за шт.
Нет голосов


Купить

В наличии
В корзину
Загрузки D1M Catalogue (PDF) [EN]
  • Описание
  • Характеристики
  • Опубликовать комментарий

D1M 20 Energy analyser for LV and MV networks, 3 or 4 wires, for balanced and unbalanced load: Voltage, current, average current, frequency, power factor, active/reactive/apparent power and energy, average active/reactive/apparent power and energy, produced/consumed energy measurement, %THDV and %THDI, 40th individual harmonic Active energy Class 0.5 according to IEC 61557-12. Auxiliary voltage: 100-230 V AC/(DC ± 15%) Din Rail mounted main unit with 1A and 5A current transformer inputs (3 module width).

Communication protocol Modbus RTU, 2 digital inputs, 2 digital outputs.

Технические характеристики

Auxiliary power supply
Voltage 100-230 V AC/DC ±15%
Frequency 50 - 60Hz ±5%
Power consumption 5VA max
Installation category CAT III 300V class per IEC 61010-1 edition 3
Protection fuse T1 A-277 VAC
Measurement Accuracy
IEC 61557-12 IEC 61557-12 PMD/S/K55/0.5
Active energy IEC61557-12 Class 0.5 / IEC 62053-22 Class 0.5S
Reactive energy IEC61557-12 Class 1 / IEC 62053-24 Class 1
Active power IEC 61557-12 Class 0.5
Reactive power IEC 61557-12 Class 1
Apparent power IEC 61557-12 Class 1
Voltage IEC 61557-12 Class 0.5
Current IEC 61557-12 Class 0.5
Frequency IEC 61557-12 Class 0.1
Neutral Current (calculated) IEC 61557-12 Class 0.1
Unbalance IEC 61557-12 Class 0.5
THD, Harmonics (current, voltage) IEC 61557-12 Class 5
Voltage Measurement inputs
Voltage input mode Direct or Indirect insertion with VT
Measurement Range 80-300 VAC(L-N)
Wiring Type Single-phase, three-phase (3P, 3P+N)
Rated frequency 50Hz or 60Hz
Protection fuse T1 A-277 VAC
VT primary range 50~750000V
VT secondary range 50~510V
Individual harmonics 2nd~40th, 0%~50%
Current measurement inputs
Ссылка на производителя: https://productid.abb.com/2TAZ665052R2001
2TAZ665052R2001