- Описание
- Характеристики
- Опубликовать комментарий
Импульсный блок питания 100 Вт со стабилизацией выхода по току. (LED драйвер). Iвых 700 мА, Uвых от 72 до 143 VDC, Pвых 100.1 Вт, Uвх от 90 до 264 VAC / от 127 до 370 VDC. IP67.
Технические характеристики
MODEL | LPC-100-700 |
---|---|
RATED CURRENT | 700mA |
CURRENT ACCURACY | ±5.0% |
CONSTANT CURRENT REGION Note.5 | 72 ~ 143V |
RATED POWER | 100.1W |
RIPPLE CURRENT | ±5% |
RIPPLE & NOISE | 1Vp-p |
LINE REGULATION | ±1% |
VOLTAGE TOLERANCE | ±1.5% |
SETUP, RISE TIME | 1000ms, 80ms / 230VAC 2000ms,80ms/115VAC at full load |
HOLD UP TIME (Typ.) | 16ms/230VAC 10ms/115vac at full load |
VOLTAGE RANGE Note.2 | 90 ~ 264VAC 127VDC ~ 370VDC |
FREQUENCY RANGE | 47 ~ 63Hz |
EFFICIENCY (Typ.) | 90% |
AC CURRENT (Typ.) | 2.2 A / 115VAC 1.2A / 230VAC |
INRUSH CURRENT (Typ.) | COLD START 75A(twidth=980μs measured at 50% Ipeak) at 230VAC |
MAX. No. of PSUs on 16A CIRCUIT BREAKER | CIRCUIT BREAKER 1 units (circuit breaker of type B) / 2 units (circuit breaker of type C) at 230VAC |
LEAKAGE CURRENT | <0,25mA/240VAC |
SHORT CIRCUIT | Hiccup mode, recovers automatically after fault condition is removed |
OVER VOLTAGE | 160 ~ 172V |
Protection type : Shut down and latch off o/p voltage re-power on to recovery | |
WORKING TEMP. | -25 ~ +50℃ (Refer to "Derating Curve") |
WORKING HUMIDITY | 10 ~ 95% RH non-condensing |
STORAGE TEMP., HUMIDITY | -40 ~ +80℃, 10 ~ 95% RH |
TEMP. COEFFICIENT | ±0.03%/℃ (0 ~ 50℃) |
VIBRATION | 10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes |
SAFETY STANDARDS | EAC TP TC 004, IP67 approved,Design refer to TUV EN60950-1 |
WITHSTAND VOLTAGE | I/P-O/P:3KVAC |
ISOLATION RESISTANCE | I/P-O/P:100M Ohms / 500VDC / 25℃/ 70% RH |
EMC EMISSION | Compliance to EN55032(CISPR32) Class B; EN61000-3-2 Class A(≦80% load); EN61000-3-3, EAC TP TC 020м |
EMC IMMUNITY | Compliance to EN61000-4-2,3,4,5,6,8,11, EN55024, light industry level , criteria A, EAC TP TC 020 |
MTBF | 511Khrs min. MIL-HDBK-217F (25℃) |
DIMENSION | 190*52*37mm (L*W*H) |
PACKING | 0.61Kg;20pcs/13.2Kg/0.55CUFT |
- All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 °С of ambient temperature.
- Derating may be needed under low input voltages. Please check the static characteristics for more details.
- The power supply is considered as a component that will be operated in combination with final equipment. Since EMC perlormance will be affected by the complete installalion, the final equipment manulamurers must re-qualily EMC Directive on lhe complete installation again.
- Refer to warranty statement.
- Constant current operation region is within 50% ~100% rated oulput voltage. This is the suitable operation region for LED related applications, but please reconfirm special electrical requirements for some specific system design.
- Suitable for indoor use or outdoor use winhout direct sunlight exposure, please avoid immerse in the water over 30minutes.
- The ambient temperature derating ol 3.5°С/1000m with finless models and of 5°С/1000m with fan models for opelating altitude higher than 2000m(6500ft].
- For any application note and IP water proof function installation caution, please refer our user manual before using. hllps://www.meanwell.com/Upload/PDF/LED_EN.pdf
- This product is not intended for LED applications in the EU.(ln the EU NPF/LPF/XLG series are recommended.)
- To fulfill requirements of latest ErP regulation for lighting luminaires, this LED Driver can only be used behind a switch without permanently connected to mains.