Источник питания для светодиодного освещения серии LPV. Входное напряжение: от 90 до 264 В. Выходная мощность 60 Вт, Выход DC 12 В. Режим стабилизации ток/напряжение: напряжение. Степень защиты: IP67. Напряжение изоляции вход-выход: 3 кВ Рабочая температура: от минус 30 до плюс 70 °C
Технические характеристики
| MODEL |
LPV-60-12 |
| DC VOLTAGE |
12V |
| RATED CURRENT |
5A |
| CURRENT RANGE |
0 ~ 5A |
| RATED POWER |
60W |
| RIPPLE & NOISE (max.) Note.2 |
120mVp-p |
| VOLTAGE TOLERANCE Note.3 |
±5.0% |
| LINE REGULATION |
±1.0% |
| LOAD REGULATION |
±2.0% |
| SETUP, RISE TIME Note.6 |
500ms, 20ms / 230VAC 500ms, 20ms / 115VAC at full load(for 5~36V) ; 500ms, 30ms / 230VAC 500ms, 30ms / 115VAC at full load(for 48V) |
| HOLD UP TIME (Typ.) |
50ms/230VAC 16ms/115VAC at full load |
| VOLTAGE RANGE Note.4 |
90 ~ 264VAC 127 ~ 370VDC |
| FREQUENCY RANGE |
47 ~ 63Hz |
| EFFICIENCY (Typ.) |
83% |
| AC CURRENT (Typ.) |
1.2A/115VAC 1A/230VAC |
| INRUSH CURRENT(Typ.) |
COLD START 60A(twidth=525μs measured at 50% Ipeak) at 230VAC |
| MAX. No. of PSUs on 16A CIRCUIT BREAKER |
3 units (circuit breaker of type B) / 6 units (circuit breaker of type C) at 230VAC |
| LEAKAGE CURRENT |
0.25mA / 240VAC |
| OVER LOAD |
110 ~ 150% rated output power |
| Protection type : Hiccup mode, recovers automatically after fault condition is removed |
| OVER VOLTAGE |
13.8 ~ 16.2V |
| Protection type : Shut down o/p voltage, re-power on to recover |
| WORKING TEMP. |
-30 ~ +70℃ (Refer to "Derating Curve") |
| WORKING HUMIDITY |
20 ~ 90% RH non-condensing |
| STORAGE TEMP., HUMIDITY |
-40 ~ +80℃, 10 ~ 95% RH |
| TEMP. COEFFICIENT |
±0.03%/℃ (0 ~ 50℃) |
| VIBRATION |
10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes |
| SAFETY STANDARDS |
UL879(except for LPV-60-5), UL1310(except for LPV-60-5), CSA C22.2 No. 207-M89(except for LPV-60-5, LPV-60-48), CAN/CSA C22.2 No. 223-M91(except for LPV-60-5,LPV-60-48), BIS IS15885(for LPV-60-12,LPV-60-24 only), EAC TP TC 004, IP67, IEC60950-1:2005+A2:2013 approved ; design refer to TUV EN60950-1 |
| WITHSTAND VOLTAGE |
I/P-O/P:3KVAC |
| ISOLATION RESISTANCE |
I/P-O/P:>100M Ohms / 500VDC / 25℃/ 70% RH |
| EMC EMISSION |
Compliance to EN55032 (CISPR32) Class B, EN61000-3-2 Class A, EN61000-3-3, EAC TP TC 020 |
| EMC IMMUNITY |
Compliance to EN61000-4-2,3,4,5,6,8,11, EN55024, light industry level, criteria A, EAC TP TC 020 |
| MTBF |
732Khrs min. MIL-HDBK-217F (25℃) |
| DIMENSION |
162.5*42.5*32mm (L*W*H) |
| PACKING |
0.4Kg; 32pcs/13.8Kg/0.63CUFT |
- All parameters NOT specially mentioned are measuted at 230VAC input, rated load and 25°C of ambient temperature.
- Ripple & noise are measuted at 20MHz of bandwidth by using a 12" twisted pair—wire terminated with a 0.1uf & 47uf parallel capacitor.
- Tolerance: includes set up tolerance, line regulation and load regulation.
- Derating may be needed under low input voltage. Please check the static characteristics for more details.
- The power supply is considered as a component that will be operated in combination with final equipment. Since EMC performanse will be affected by the complete installation, the final equipment manufacturers must re-quality EMC Directive on the complete installation again.
- Length of set up time is measured at first cold start. Turning ON/OFF the power supply may lead to increase of the set up time.
- Suitable for indoor use or outdoor use without direct sunlight exposure. Please avoid immerse in the water over 30 minute.
- The ambient temperatute derating of 3.5°C/1000m with fanless models and of 5°C/1000m with fan models for operating altitude higher than 2000m(6500ft).
- For any application note and IP water proof function installation caution, please refer our user manual befote using. https://www.meanwell.com/Upload/PDF/LED_EN.pdf
- This product is not intended for LED applications in the EU.(ln the EU NPF/LPF/XLG series are recommended.)
- To fulfill requirements of latest ErP regulation for lighting luminaires, this LED Driver can only be used behind a switch without permanently connected to mains.